Subject: CMULTIS012-1 Segment: UpperArm Modality: Compare MRI and CT Sphere Fitting - CT STL Marker Radius (mm) Coordinates [x,y,z] (mm) H1 9.29 -4.6666, 248.8234, 1276.4824 H2 9.34 23.4846, 217.8857, 1234.3303 H3 9.41 -21.8870, 230.6881, 1238.3978 H4 9.47 11.8448, 150.5969, 955.9629 Distances between markers Marker 1 Marker 2 Distance (mm) H1 H2 59.38 H1 H3 45.56 H1 H4 335.64 H2 H3 47.32 H2 H4 286.62 H3 H4 295.50 Sphere Fitting - MRI STL Marker Radius (mm) Coordinates [x,y,z] (mm) H1 8.63 -4.5363, 249.3728, 1277.9934 H2 8.40 23.7826, 217.7952, 1234.3092 H3 8.16 -22.4247, 230.6907, 1238.4554 H4 8.21 11.9542, 150.1355, 954.4154 Distances between markers Marker 1 Marker 2 Distance (mm) H1 H2 60.89 H1 H3 47.25 H1 H4 338.86 H2 H3 48.15 H2 H4 288.20 H3 H4 297.24 Differences between CT and MRI registration Marker 1 Marker 2 Distance Diff Angle(deg) H1 H2 -1.50 mm [-2.53 %] 0.69 H1 H3 -1.69 mm [-3.70 %] 0.16 H1 H4 -3.22 mm [-0.96 %] 0.03 H2 H3 -0.83 mm [-1.76 %] 0.16 H2 H4 -1.58 mm [-0.55 %] 0.02 H3 H4 -1.73 mm [-0.59 %] 0.09 Average 1.76 mm [1.68 %] 0.19 Maximum 3.22 mm [3.70 %] 0.69