Subject: CMULTIS012-1 Segment: LowerLeg Modality: MRI Digitized Points Sphere Fitting Marker Radius (mm) Coordinates [x,y,z] (mm) T1 10.00 85.9852, 25.8878, 103.7425 T2 10.77 35.8959, 12.2374, 99.3776 T3 8.74 26.5909, -24.3046, 94.6055 T4 10.74 46.1842, -0.8688, -192.0053 T5 10.14 29.5645, -2.9124, -260.5171 Distances between markers Marker 1 Marker 2 Distance (mm) T1 T2 52.10 T1 T3 78.30 T1 T4 299.61 T1 T5 369.73 T2 T3 38.01 T2 T4 291.86 T2 T5 360.27 T3 T4 288.23 T3 T5 355.78 T4 T5 70.53 Sphere Fitting - MRI STL Marker Radius (mm) Coordinates [x,y,z] (mm) T1 8.38 87.0627, 26.2343, 104.7824 T2 8.23 35.2351, 12.7452, 98.8938 T3 8.14 26.3514, -25.1122, 94.5149 T4 8.46 46.0673, -0.8244, -191.6590 T5 8.66 29.5042, -3.0036, -261.3290 Distances between markers Marker 1 Marker 2 Distance (mm) T1 T2 53.88 T1 T3 80.17 T1 T4 300.48 T1 T5 371.76 T2 T3 39.13 T2 T4 291.07 T2 T5 360.61 T3 T4 287.88 T3 T5 356.54 T4 T5 71.64 Differences between digitized and MRI registration Marker 1 Marker 2 Distance Diff Angle(deg) T1 T2 1.78 mm [3.30 %] 1.61 T1 T3 1.88 mm [2.34 %] 0.66 T1 T4 0.87 mm [0.29 %] 0.21 T1 T5 2.03 mm [0.55 %] 0.14 T2 T3 1.12 mm [2.87 %] 1.33 T2 T4 -0.79 mm [-0.27 %] 0.15 T2 T5 0.34 mm [0.10 %] 0.13 T3 T4 -0.36 mm [-0.12 %] 0.18 T3 T5 0.77 mm [0.21 %] 0.11 T4 T5 1.12 mm [1.56 %] 0.28 Average 1.11 mm [1.16 %] 0.48 Maximum 2.03 mm [3.30 %] 1.61