Subject: CMULTIS011-1 Segment: LowerLeg Modality: MRI Digitized Points Sphere Fitting Marker Radius (mm) Coordinates [x,y,z] (mm) T1 11.98 156.3538, 6.0593, -26.8656 T2 9.90 88.8662, 22.5943, -45.4835 T3 9.84 71.1008, -15.4199, -43.0044 T4 10.75 121.2353, 25.2694, -288.1904 T5 9.90 123.0174, 31.8709, -406.5658 Distances between markers Marker 1 Marker 2 Distance (mm) T1 T2 71.93 T1 T3 89.39 T1 T4 264.37 T1 T5 382.03 T2 T3 42.03 T2 T4 244.87 T2 T5 362.81 T3 T4 253.55 T3 T5 370.28 T4 T5 118.57 Sphere Fitting - MRI STL Marker Radius (mm) Coordinates [x,y,z] (mm) T1 8.83 158.9072, 6.6447, -25.6598 T2 8.85 88.2941, 21.4218, -46.1078 T3 8.58 69.0820, -14.8768, -43.6312 T4 8.84 121.7920, 25.3628, -288.6586 T5 8.89 122.4982, 31.8216, -406.0523 Distances between markers Marker 1 Marker 2 Distance (mm) T1 T2 74.98 T1 T3 94.10 T1 T4 266.26 T1 T5 382.96 T2 T3 41.14 T2 T4 244.88 T2 T5 361.72 T3 T4 253.84 T3 T5 369.30 T4 T5 117.57 Differences between digitized and MRI registration Marker 1 Marker 2 Distance Diff Angle(deg) T1 T2 3.05 mm [4.07 %] 2.05 T1 T3 4.71 mm [5.01 %] 0.89 T1 T4 1.89 mm [0.71 %] 0.40 T1 T5 0.93 mm [0.24 %] 0.46 T2 T3 -0.89 mm [-2.16 %] 2.84 T2 T4 0.01 mm [0.01 %] 0.40 T2 T5 -1.10 mm [-0.30 %] 0.18 T3 T4 0.30 mm [0.12 %] 0.59 T3 T5 -0.98 mm [-0.27 %] 0.27 T4 T5 -1.00 mm [-0.85 %] 0.52 Average 1.49 mm [1.37 %] 0.86 Maximum 4.71 mm [5.01 %] 2.84