Subject: CMULTIS008-1 Segment: LowerArm Modality: Compare MRI and CT Sphere Fitting - CT STL Marker Radius (mm) Coordinates [x,y,z] (mm) R1 9.33 1.6117, 155.2444, 5.4503 R2 9.46 32.6649, 157.4395, -213.3621 R3 9.52 6.5434, 181.7417, -226.4590 Distances between markers Marker 1 Marker 2 Distance (mm) R1 R2 221.02 R1 R3 233.47 R2 R3 38.01 Sphere Fitting - MRI STL Marker Radius (mm) Coordinates [x,y,z] (mm) R1 8.12 1.6090, 155.2449, 5.4640 R2 8.20 32.7617, 157.3523, -213.3349 R3 8.35 6.4493, 181.8284, -226.4998 Distances between markers Marker 1 Marker 2 Distance (mm) R1 R2 221.02 R1 R3 233.53 R2 R3 38.27 Differences between CT and MRI registration Marker 1 Marker 2 Distance Diff Angle(deg) R1 R2 0.00 mm [0.00 %] 0.03 R1 R3 -0.06 mm [-0.03 %] 0.03 R2 R3 -0.27 mm [-0.70 %] 0.04 Average 0.11 mm [0.24 %] 0.03 Maximum 0.27 mm [0.70 %] 0.04