Subject: CMULTIS007-1 Segment: UpperLeg Modality: MRI Digitized Points Sphere Fitting Marker Radius (mm) Coordinates [x,y,z] (mm) F1 9.69 35.6144, 52.9442, 34.4141 F2 9.75 59.7109, 41.3918, 18.3032 F3 9.82 20.8469, 41.0250, 0.5413 F4 9.98 71.2244, -13.3992, -358.1090 F5 10.09 57.7276, 8.8965, -345.8558 F6 10.09 -13.9758, -16.5690, -330.9398 Distances between markers Marker 1 Marker 2 Distance (mm) F1 F2 31.20 F1 F3 38.83 F1 F4 399.68 F1 F5 383.45 F1 F6 375.20 F2 F3 42.73 F2 F4 380.55 F2 F5 365.61 F2 F6 361.61 F3 F4 366.24 F3 F5 349.83 F3 F6 338.24 F4 F5 28.80 F4 F6 89.48 F5 F6 77.54 Sphere Fitting - MRI STL Marker Radius (mm) Coordinates [x,y,z] (mm) F1 8.13 35.7173, 53.0707, 35.5742 F2 8.20 60.0035, 41.5708, 19.0373 F3 8.26 20.6142, 41.0612, 0.7527 F4 8.47 72.0680, -13.4847, -358.6961 F5 8.23 57.8592, 8.9423, -346.2911 F6 8.02 -15.1137, -16.8712, -332.0230 Distances between markers Marker 1 Marker 2 Distance (mm) F1 F2 31.55 F1 F3 39.81 F1 F4 401.50 F1 F5 385.04 F1 F6 377.63 F2 F3 43.43 F2 F4 381.92 F2 F5 366.79 F2 F6 363.73 F3 F4 367.19 F3 F5 350.51 F3 F6 339.66 F4 F5 29.30 F4 F6 91.23 F5 F6 78.71 Differences between digitized and MRI registration Marker 1 Marker 2 Distance Diff Angle(deg) F1 F2 0.35 mm [1.10 %] 0.57 F1 F3 0.98 mm [2.47 %] 0.34 F1 F4 1.82 mm [0.45 %] 0.08 F1 F5 1.59 mm [0.41 %] 0.02 F1 F6 2.43 mm [0.64 %] 0.14 F2 F3 0.70 mm [1.61 %] 0.38 F2 F4 1.36 mm [0.36 %] 0.08 F2 F5 1.18 mm [0.32 %] 0.02 F2 F6 2.13 mm [0.58 %] 0.16 F3 F4 0.95 mm [0.26 %] 0.15 F3 F5 0.68 mm [0.19 %] 0.05 F3 F6 1.42 mm [0.42 %] 0.13 F4 F5 0.51 mm [1.72 %] 1.07 F4 F6 1.75 mm [1.92 %] 0.68 F5 F6 1.17 mm [1.48 %] 0.65 Average 1.27 mm [0.93 %] 0.30 Maximum 2.43 mm [2.47 %] 1.07