Subject: CMULTIS006-1 Segment: UpperArm Modality: Compare MRI and CT Sphere Fitting - CT STL Marker Radius (mm) Coordinates [x,y,z] (mm) H1 9.26 34.6439, 227.6245, -43.4171 H2 9.48 54.8861, 196.8793, -98.7032 H3 9.24 7.2967, 222.7471, -70.7788 H4 9.38 4.8782, 169.9376, -314.4972 Distances between markers Marker 1 Marker 2 Distance (mm) H1 H2 66.42 H1 H3 38.99 H1 H4 278.74 H2 H3 60.94 H2 H4 223.15 H3 H4 249.39 Sphere Fitting - MRI STL Marker Radius (mm) Coordinates [x,y,z] (mm) H1 8.42 34.7699, 227.8358, -42.3151 H2 7.95 55.2140, 196.7784, -98.6043 H3 8.27 7.0207, 222.8653, -70.8154 H4 8.28 4.7003, 169.7091, -315.6614 Distances between markers Marker 1 Marker 2 Distance (mm) H1 H2 67.46 H1 H3 40.09 H1 H4 281.07 H2 H3 61.44 H2 H4 224.50 H3 H4 250.56 Differences between CT and MRI registration Marker 1 Marker 2 Distance Diff Angle(deg) H1 H2 -1.04 mm [-1.57 %] 0.21 H1 H3 -1.10 mm [-2.81 %] 0.75 H1 H4 -2.33 mm [-0.83 %] 0.01 H2 H3 -0.50 mm [-0.83 %] 0.39 H2 H4 -1.35 mm [-0.61 %] 0.05 H3 H4 -1.17 mm [-0.47 %] 0.03 Average 1.25 mm [1.19 %] 0.24 Maximum 2.33 mm [2.81 %] 0.75