Subject: CMULTIS005-1 Segment: LowerLeg Modality: Compare MRI and CT Sphere Fitting - CT STL Marker Radius (mm) Coordinates [x,y,z] (mm) T1 9.50 54.7633, 198.8644, 533.4175 T2 9.60 -13.7727, 199.0077, 502.4832 T3 9.80 -33.5107, 157.6359, 531.5332 T4 9.59 6.3748, 208.5920, 390.1262 T5 9.54 0.6169, 208.3929, 242.5792 T6 9.59 -35.3083, 189.1312, 220.0048 Distances between markers Marker 1 Marker 2 Distance (mm) T1 T2 75.19 T1 T3 97.45 T1 T4 151.55 T1 T5 295.99 T1 T6 326.24 T2 T3 54.27 T2 T4 114.55 T2 T5 260.47 T2 T6 283.47 T3 T4 155.51 T3 T5 295.36 T3 T6 313.12 T4 T5 147.66 T4 T6 176.23 T5 T6 46.60 Sphere Fitting - MRI STL Marker Radius (mm) Coordinates [x,y,z] (mm) T1 8.13 55.5479, 198.8384, 534.7828 T2 8.37 -14.1131, 198.9720, 502.0058 T3 8.26 -33.7565, 157.6148, 532.4121 T4 7.92 6.3982, 208.4251, 390.1323 T5 8.21 0.3599, 208.8837, 241.3773 T6 7.84 -35.2730, 188.8902, 219.4339 Distances between markers Marker 1 Marker 2 Distance (mm) T1 T2 76.99 T1 T3 98.39 T1 T4 153.07 T1 T5 298.72 T1 T6 328.32 T2 T3 54.96 T2 T4 114.13 T2 T5 261.22 T2 T6 283.54 T3 T4 156.33 T3 T5 297.48 T3 T6 314.54 T4 T5 148.88 T4 T6 176.79 T5 T6 46.38 Differences between CT and MRI registration Marker 1 Marker 2 Distance Diff Angle(deg) T1 T2 -1.79 mm [-2.38 %] 0.91 T1 T3 -0.94 mm [-0.97 %] 0.37 T1 T4 -1.52 mm [-1.00 %] 0.14 T1 T5 -2.73 mm [-0.92 %] 0.13 T1 T6 -2.07 mm [-0.64 %] 0.04 T2 T3 -0.69 mm [-1.28 %] 1.23 T2 T4 0.42 mm [0.37 %] 0.23 T2 T5 -0.75 mm [-0.29 %] 0.11 T2 T6 -0.07 mm [-0.03 %] 0.09 T3 T4 -0.82 mm [-0.52 %] 0.16 T3 T5 -2.12 mm [-0.72 %] 0.06 T3 T6 -1.42 mm [-0.45 %] 0.08 T4 T5 -1.22 mm [-0.83 %] 0.27 T4 T6 -0.56 mm [-0.32 %] 0.05 T5 T6 0.22 mm [0.47 %] 1.21 Average 1.16 mm [0.75 %] 0.34 Maximum 2.73 mm [2.38 %] 1.23