Subject: CMULTIS005-1 Segment: LowerArm Modality: Compare MRI and CT Sphere Fitting - CT STL Marker Radius (mm) Coordinates [x,y,z] (mm) R1 9.21 27.5051, 168.7605, 833.6376 R2 9.07 43.2581, 154.0735, 634.7691 R3 9.13 29.8599, 186.8220, 613.1213 Distances between markers Marker 1 Marker 2 Distance (mm) R1 R2 200.03 R1 R3 221.27 R2 R3 41.48 Sphere Fitting - MRI STL Marker Radius (mm) Coordinates [x,y,z] (mm) R1 8.13 27.5059, 168.7568, 833.6548 R2 8.02 43.3357, 153.8819, 634.9111 R3 7.97 29.7814, 187.0173, 612.9620 Distances between markers Marker 1 Marker 2 Distance (mm) R1 R2 199.93 R1 R3 221.46 R2 R3 41.99 Differences between CT and MRI registration Marker 1 Marker 2 Distance Diff Angle(deg) R1 R2 0.10 mm [0.05 %] 0.06 R1 R3 -0.19 mm [-0.09 %] 0.05 R2 R3 -0.51 mm [-1.24 %] 0.05 Average 0.27 mm [0.46 %] 0.06 Maximum 0.51 mm [1.24 %] 0.06