Subject: CMULTIS005-1 Segment: UpperArm Modality: MRI Digitized Points Sphere Fitting Marker Radius (mm) Coordinates [x,y,z] (mm) H1 9.87 23.2331, 31.0009, -14.1215 H2 9.79 51.6308, 21.0210, -44.4256 H3 9.87 19.9065, -2.4075, -42.7598 H4 9.47 56.3599, -25.8215, -269.9651 Distances between markers Marker 1 Marker 2 Distance (mm) H1 H2 42.71 H1 H3 44.13 H1 H4 264.16 H2 H3 39.47 H2 H4 230.40 H3 H4 231.30 Sphere Fitting - MRI STL Marker Radius (mm) Coordinates [x,y,z] (mm) H1 8.12 23.2578, 30.9194, -12.9430 H2 8.13 51.7904, 21.4105, -44.3738 H3 8.25 19.6492, -2.4624, -43.3952 H4 8.15 56.4328, -26.0746, -270.5600 Distances between markers Marker 1 Marker 2 Distance (mm) H1 H2 43.50 H1 H3 45.33 H1 H4 265.92 H2 H3 40.05 H2 H4 231.16 H3 H4 231.33 Differences between digitized and MRI registration Marker 1 Marker 2 Distance Diff Angle(deg) H1 H2 0.79 mm [1.81 %] 1.25 H1 H3 1.20 mm [2.65 %] 1.78 H1 H4 1.76 mm [0.66 %] 0.06 H2 H3 0.58 mm [1.44 %] 1.03 H2 H4 0.76 mm [0.33 %] 0.13 H3 H4 0.03 mm [0.01 %] 0.10 Average 0.85 mm [1.15 %] 0.72 Maximum 1.76 mm [2.65 %] 1.78