Subject: CMULTIS005-1 Segment: UpperArm Modality: CT Digitized Points Sphere Fitting Marker Radius (mm) Coordinates [x,y,z] (mm) H1 9.87 -16.6276, 230.1607, 1125.6989 H2 9.79 12.1802, 220.3146, 1095.7400 H3 9.87 -19.4292, 196.7090, 1097.0549 H4 9.47 19.8240, 173.3026, 870.3157 Distances between markers Marker 1 Marker 2 Distance (mm) H1 H2 42.71 H1 H3 44.13 H1 H4 264.16 H2 H3 39.47 H2 H4 230.40 H3 H4 231.30 Sphere Fitting - CT STL Marker Radius (mm) Coordinates [x,y,z] (mm) H1 9.15 -16.6552, 230.0798, 1125.6982 H2 9.09 12.2334, 220.3004, 1095.5369 H3 9.11 -19.3747, 196.7306, 1096.6539 H4 9.21 19.7438, 173.3762, 870.9205 Distances between markers Marker 1 Marker 2 Distance (mm) H1 H2 42.89 H1 H3 44.31 H1 H4 263.54 H2 H3 39.44 H2 H4 229.59 H3 H4 230.29 Differences between digitized and CT registration Marker 1 Marker 2 Distance Diff Angle(deg) H1 H2 0.18 mm [0.42 %] 0.18 H1 H3 0.18 mm [0.40 %] 0.49 H1 H4 -0.63 mm [-0.24 %] 0.01 H2 H3 -0.03 mm [-0.07 %] 0.29 H2 H4 -0.81 mm [-0.35 %] 0.03 H3 H4 -1.01 mm [-0.44 %] 0.02 Average 0.47 mm [0.32 %] 0.17 Maximum 1.01 mm [0.44 %] 0.49